Page 3( total 6pages) Page up Page down    

 

1.Battery Charging
This is the recommended method of charging for Suneom batteries. It is necessary to closely control the actual voltage to ensure that it is within the limits advised.
> Float charge: charge voltage 2.275V/unit(at 20℃) ,below 0.002CA floating electric. when the temperature is below 0℃ or above 40℃,it is necessary to modify electric voltage which according with the starting point 20℃, unit voltage will change -3 mV/℃/cell.
> Cycle charge: electric voltage 2.4~2.5V/unit(at 20℃),When the temperature is below 5℃ or above 35℃ which according with the starting point 20℃ to change, unit voltage will change -4 mV/℃/cell.
>charge electric quality set at discharge’s 100~120%. When ambient temperature below 5℃, it should be set at 120~ 130%.

>the temperature should be within -15℃~+50℃ when battery charging, pay attention to the temperature should be within 5℃~30℃ when circle using.
 
    2. Battery discharging
.>the temperature should be within -15℃~+50℃ when battery discharging
>the continuous discharge current should be below 3CA. SH series battery’s should be below 6CA.
The affordable discharge current of different terminal are following:
 